OPERATING PROCEDURE "LEVELOUT" STORE MORE ROOM EXTENSION MECHANISM
MANUAL ROOM RETRACTION PROCEDURES
Performed On a 2005 Winnebago Voyage 38J
1. Determine which extend and retract solenoid valves are
assigned to the room. Manually open the valve release nuts
for the extend and retract solenoid valves by turning the 1/4"
release nuts counter clockwise 4 and 1/2 turns. Turning the
2. Gain access to the 13/16" Manual Retraction Bolts (one
on each mechanism) by raising the STOREMORE access
panel.
3. Remove the Thumb Screws (one on each mechanism)
completely by turning them counterclockwise.
4. Using wrench provided, a personal wrench or a tire iron
with a 13/16" or 21mm opening rotate either mechanism’s
Manual Retraction Bolt clockwise 5 complete turns.
5. Move to the second room extension mechanism, rotate
the Manual Retraction Bolt clockwise 10 complete turns
6. Return to the first room extension mechanism and rotate
the Manual Retraction Bolt clockwise 5 complete turns.
7. Repeat steps 4 and 5 alternating from mechanism to
mechanism rotating each Manual Retraction Bolt 5
complete turns until room is sealed. (DO NOT exceed 15
ft.lbs) Make sure the room does not bind.
8. Replace both Thumb Screws. Leave the manual valve
releases open.
IMPORTANT: DO NOT EXTEND THE ROOM
UNTIL THE STEPS BELOW HAVE BEEN
COMPLETED!
1. Gain access to the 13/16" Manual Retraction Bolts (one
on each mechanism) by raising the STOREMORE access
panel
2. Remove the Thumb Screws (one on each mechanism)
completely by turning them counterclockwise
3. If needed, using wrench provided, a personal wrench or
a tire iron with a 13/16" or 21mm opening rotate either
mechanism’s Manual Retraction Bolt counterclockwise until
resistance is met.
4. Move to the second room extension mechanism and
repeat step 3
5. Replace both Thumb Screws.

6. Close both manual valve releases assigned to the
room. Turn the valve release nuts clockwise until snug.
DO NOT over tighten.